Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Dental Press J Orthod ; 28(6): e2323175, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38198390

RESUMO

OBJECTIVE: This randomized crossover trial evaluated periodontal indexes of two types of 3 x 3 retainers (a modified 0.032-in SS V-loop retainer and a conventional 0.0215-in SS coaxial wire retainer) after bonded for six months. Also, bonded failure rate, and a questionnaire about comfort, ease of cleaning and overall preference were recorded. MATERIAL AND METHODS: 15 patients were enrolled in this study who used both retainers for six months each, having a 15-day wash-out interval between each bonded retainer usage. The following periodontal index were recorded: Plaque Index (PI), Calculus Index (CI) and Gingival Index (GI). Patients answered a questionnaire to assess comfort, ease of cleaning and overall retainer-type preference. Rate of bonding failure was also evaluated. RESULTS: V-Loop retainer showed higher PI (P<0.05) as compared to conventional 0.0215-in coaxial wire retainer. However, CI and GI presented no statistically significant differences between both types of retainers. The conventional 0.0215-in coaxial wire retainer was chosen as the most comfortable (p<0.05), although no statistically significant differences were found for all other questionnaire answers. Bonding failure events were more observed in the 3x3 V-Loop retainer (p<0.002), as compared to the conventional 0.0215-in coaxial retainer. CONCLUSION: V-Loop retainer showed higher PI (p<0.05), higher bonding failure rate and less comfortable, as compared to conventional 0.0215-in coaxial wire.


Assuntos
Aparelhos Ortodônticos Fixos , Registros , Humanos , Estudos Cross-Over , Índice Periodontal
2.
Dental press j. orthod. (Impr.) ; 28(6): e2323175, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528518

RESUMO

ABSTRACT Objective: This randomized crossover trial evaluated periodontal indexes of two types of 3 x 3 retainers (a modified 0.032-in SS V-loop retainer and a conventional 0.0215-in SS coaxial wire retainer) after bonded for six months. Also, bonded failure rate, and a questionnaire about comfort, ease of cleaning and overall preference were recorded. Material and Methods: 15 patients were enrolled in this study who used both retainers for six months each, having a 15-day wash-out interval between each bonded retainer usage. The following periodontal index were recorded: Plaque Index (PI), Calculus Index (CI) and Gingival Index (GI). Patients answered a questionnaire to assess comfort, ease of cleaning and overall retainer-type preference. Rate of bonding failure was also evaluated. Results: V-Loop retainer showed higher PI (P<0.05) as compared to conventional 0.0215-in coaxial wire retainer. However, CI and GI presented no statistically significant differences between both types of retainers. The conventional 0.0215-in coaxial wire retainer was chosen as the most comfortable (p<0.05), although no statistically significant differences were found for all other questionnaire answers. Bonding failure events were more observed in the 3x3 V-Loop retainer (p<0.002), as compared to the conventional 0.0215-in coaxial retainer. Conclusion: V-Loop retainer showed higher PI (p<0.05), higher bonding failure rate and less comfortable, as compared to conventional 0.0215-in coaxial wire.


RESUMO Objetivo: Este estudo cruzado e randomizado avaliou os índices periodontais de dois tipos de contenções 3x3 (uma contenção aço V-Loop de 0,032" modificada e uma contenção convencional de fio coaxial aço de 0,0215") após colagem, por seis meses. Além disso, foram registradas a taxa de falha na colagem e um questionário sobre conforto, facilidade de limpeza e preferência geral. Material e Métodos: Foram incluídos nesse estudo 15 pacientes que usaram ambas as contenções por seis meses cada, com intervalo de quinze dias entre cada contenção fixa. Foram registrados os seguintes índices periodontais: Índice de Placa (IP), Índice de Cálculo (IC) e Índice Gengival (IG). Os pacientes responderam a um questionário para avaliar o conforto, a facilidade de limpeza e a preferência geral pelo tipo de contenção. A taxa de falha de colagem também foi avaliada. Resultados: A contenção V-Loop apresentou maior IP (p<0,05) em comparação ao fio coaxial convencional. Entretanto, IC e IG não apresentaram diferenças estatisticamente significativas entre as contenções testadas. A contenção convencional de fio coaxial 0,0215" foi escolhida como a mais confortável (p<0,05), embora não tenham sido encontradas diferenças estatisticamente significativas para todas as outras respostas do questionário. Eventos de falha de colagem foram mais observados na contenção V-Loop 3 x 3 (p<0,002) em comparação com a contenção coaxial convencional de 0,0215". Conclusão: A contenção V-Loop apresentou maior IP (p<0,05), maior taxa de falha de colagem e foi menos confortável em comparação ao fio coaxial convencional 0,0215".

3.
Artigo em Inglês | MEDLINE | ID: mdl-32454953

RESUMO

Background. This study evaluated the phase transformation of NiTi orthodontic wires and forces they release on deactivation. Methods. The structural phase transformations of the following five thermo-activated nickel-titanium (NiTi) wires were evaluated using differential scanning calorimetry (DSC): Flexy Thermal Sentalloy® (GAC International), NiTi (35ºC) (Eurodonto), Thermo-Plus® (Morelli), FlexyNiTi® Flexy Thermal (35ºC) (Orthometric) and Damon® CuNiTi (35ºC) (ORMCO Corp.). The wires had a cross-section of 0.40 mm (0.016"). In addition, the forces they released were investigated using the three-point bending test. Five arches of each wire were tested using DSC (-20/80ºC at 10ºC/min), and six arches from each wire were sectioned for bending tests. The data were analyzed with ANOVA and post hoc Tukey tests. Pearson's correlation test was performed between the results yielded by the DSC tests and those by three-point analyses (P=0.05). Results. The DSC analysis showed differences between the NiTi alloys from all the manufacturers, with no differences between the lots of the same brand. ORMCO and Orthometric wires exhibited similar TTR values in cooling (P=0.49), and statistically similar TTR values in heating (P=0.056). The three-point bending test showed different patterns in releasing forces. A correlation was found between the DSC analysis and the three-point bending test results. Conclusion. The higher the temperature transformation was, the larger was the variation of force. All the wires presented higher forces at 3-mm deflection from 155 (±12.3) to 168.1 (±8) cN. The DSC analysis and the three-point bending test showed differences between the NiTi alloys from all the manufacturers.

4.
Dent. press implantol ; 8(1): 81-85, Jan.-Mar.2014.
Artigo em Português | LILACS | ID: lil-742394

RESUMO

Introdução: a relação entre doença periodontal (DP), e doença renal crônica (DRC), é bidirecional, uma vez que, além das manifestações bucais presentes em indivíduos com DRC, a presença da DP se torna um fator complicador dessa patologia renal. A resposta inflamatória sistêmica que ocorre em pacientes periodontais pode ter um efeito sinérgico na inflamação crônica presente na DRC. Objetivo: buscar na literatura evidências que demonstrem a importância da relação entre essas duas condições. Métodos: levantamento no banco de dados PubMed, no período entre 2003 e 2013. Foram selecionados estudos clínicos e revisões sistemáticas. Resultados: seis estudos clínicos e uma revisão sistemática preencheram os critérios estabelecidos. Os estudos clínicos apresentam diferentes formas de abordagem quanto à relação entre DP e DRC. Houve busca pela associação entre DP e DRC em estudo cruzado e das manifestações bucais em pacientes renais, além de se buscar avaliar o efeito do tratamento periodontal nos marcadores da doença renal. Conclusão: foi observado que a DRC, ao afetar as funções sistêmicas do organismo, também afeta a saúde bucal desses pacientes, com especial ação nos tecidos periodontais. Além disso, a DP também é capaz de afetar a função renal, trazendo complicações para indivíduos com DRC...


Introduction: The association between periodontal disease (PD) and chronic kidney disease (CKD) is bidirectional, as individuals with CKD may have oral manifestations, and PD may develop as a complicating factor of CKD. The systemic inflammatory response found in periodontal patients may have a synergistic effect on the chronic inflammation found in CKD. Objective: To review the literature to find evidence of the importance of the association between these two conditions. Methods: A PubMed search of studies published between 2003 and 2013 was conducted to retrieve clinical trials and systematic reviews. Results: Six clinical trials and one systematic review met the established criteria. Clinical trials used different approaches for the association between PD and CKD. Studies investigating the association between PD and CKD used a crossover design, evaluation of the oral manifestations in patients with CKD, and analysis of the effect of periodontal treatment on markers of renal disease. Conclusion: In addition to systemic functions, CKD also affects oral health, particularly causing periodontal tissues. Moreover, PD may affect kidney functions and lead to complications in individuals with CKD...


Assuntos
Humanos , Doenças Periodontais/complicações , Insuficiência Renal Crônica/complicações , Brasil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...